At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- PowerAssist adds battery power when AC power is limited
- Connects to a Cerbo GX for monitoring and control over VE.Bus
- Can run in parallel or three-phase systems
Key specs
- AC Input voltage range: 95 to 140 VAC
- Continuous inverter AC output power at 25 C: 1,000 W
- Peak power rating: 2,400 W
- Maximum efficiency: 93 %
- Operating temperature range (fan assisted cooling): -40 to 65 C
| Specification | Value |
|---|---|
| Continuous inverter AC output power at 25 C | 1,000 W |
| AC Input voltage range | 95 to 140 VAC |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| Nominal battery voltage | 12 V |
| Charge algorithm | Adaptive, 4-stage |
| Charge voltage absorption (adjustable) | 14.4 VDC |
| Charge voltage float (adjustable) | 13.8 VDC |
| Charge voltage storage (adjustable) | 13.2 VDC |
| Communication Port | VE.Bus |
| Programming via computer or app | Yes |
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 1,200 VA |
| AC input frequency range | 55 to 65 Hz |
| Continuous inverter AC output power at 40 C | 900 W |
| Continuous inverter AC output power at 65 C | 600 W |
| DC Input voltage range | 9.5 to 17 VDC |
| DIP switches for programming | Yes |
| Fan assisted cooling | Yes |
| Internal DC fuse rating | 200 A |
| Maximum efficiency | 93 % |
| Maximum humidity (non-condensing) | 95 % |
| Maximum charge current (up to 25 C ambient) | 50 A |
| Temperature Sensor | Included |
| Number of AC Inputs | 1 |
| Number of AC Outputs | 1 |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Parallel operation | Yes |
| Peak power rating | 2,400 W |
| PowerAssist | Yes |
| PowerControl | Yes |
| Programmable relay | AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Remote terminal | On / Off / Charger only |
| Three phase operation | Yes |
| Transfer switch AC current rating | 16 A |
| Zero Load Power | 13 W |
| Zero load power in search mode | 4 W |
| Remote terminal type | Screw terminal two pole |
| Relay terminal type | Screw terminal 3-pole |
| AC connection terminal type | G-ST18i plug |
| Battery connection terminal type | Screw terminals 35 mm2 (2 AWG) |
| VE.bus communication port | One RJ45 terminal, RJ45-spliter ASS030065510 to expand to two ports |
| Height | 406 mm |
| Depth | 100 mm |
| Colour | Blue (RAL 5012) |
- MultiPlus 12/1200/50-16
- Temperature sensor
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.
Alternative Products