At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- PowerAssist adds battery power when AC power is limited
- Connects to a Cerbo GX for monitoring and control over VE.Bus
- Can run in parallel or three-phase systems
Key specs
- DC Input voltage range: 19 to 33 VDC
- Starter battery charge current: 4 A
- Peak power rating: 6,000 W
- Maximum efficiency: 94 %
- Operating temperature range (fan assisted cooling): -40 to 65 C
| Specification | Value |
|---|---|
| Power Factor | 1 |
| Remote terminal | On / Off / Charger only |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Programmable relay | AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| Starter battery charge current | 4 A |
| PowerControl | Yes |
| PowerAssist | Yes |
| Peak power rating | 6,000 W |
| Parallel operation | Yes |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Starter battery charge output | Yes |
| Temperature Sensor | Included |
| Three phase operation | Yes |
| Transfer switch AC current rating | 50 A |
| Zero Load Power | 20 W |
| Zero load power in AES mode | 15 W |
| Zero load power in search mode | 10 W |
| Number of AC Outputs | 2 |
| Continuous inverter AC output power at 25 C | 2,400 W |
| DIP switches for programming | Yes |
| DC Input voltage range | 19 to 33 VDC |
| Continuous inverter AC output power at 65 C | 1,700 W |
| Continuous inverter AC output power at 40 C | 2,200 W |
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 3,000 VA |
| Programming via computer or app | Yes |
| General purpose communication port | Yes |
| Communication Port | VE.Bus |
| Charge voltage storage (adjustable) | 26.4 VDC |
| Fan assisted cooling | Yes |
| Maximum efficiency | 94 % |
| Maximum humidity (non-condensing) | 95 % |
| Maximum charge current (up to 25 C ambient) | 70 A |
| Number of AC Inputs | 1 |
| AC input frequency range | 45 to 65 Hz |
| AC Input voltage range | 95 to 140 VAC |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| Auxiliary AC output | Yes |
| Nominal battery voltage | 24 V |
| Charge algorithm | Adaptive, 4-stage |
| Charge voltage absorption (adjustable) | 28.8 VDC |
| Charge voltage float (adjustable) | 27.6 VDC |
| AC connection terminal type | Screw terminals 13 mm2 (6 AWG) |
| Battery connection terminal type | M8 bolts (two for positive and two for negative connection) |
| Relay terminal type | Screw terminal 3-pole |
- MultiPlus 24/3000/70-50
- Temperature sensor
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.