At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- PowerAssist adds battery power when AC power is limited
- Connects to a Cerbo GX for monitoring and control over VE.Bus
- Can run in parallel or three-phase systems
Key specs
- DC Input voltage range: 19 to 33 VDC
- Maximum charge current (up to 25 C ambient): 70 A
- Peak power rating: 5,500 W
- Maximum efficiency: 94 %
- Operating temperature range (fan assisted cooling): -40 to 65 C
| Specification | Value |
|---|---|
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 3,000 VA |
| Maximum charge current (up to 25 C ambient) | 70 A |
| Maximum humidity (non-condensing) | 95 % |
| Maximum efficiency | 94 % |
| Maximum AC input current | 50 A |
| Fan assisted cooling | Yes |
| External AC Current Sensor | 100A (optional) |
| DC Input voltage range | 19 to 33 VDC |
| Continuous inverter AC output power at 65 C | 1,700 W |
| Continuous inverter AC output power at 40 C | 2,200 W |
| Continuous inverter AC output power at 25 C | 2,400 W |
| Number of AC Inputs | 1 |
| Programming via computer or app | Yes |
| General purpose communication port | Yes |
| Communication Port | VE.Bus |
| Charge voltage storage (adjustable) | 26.4 VDC |
| Charge voltage float (adjustable) | 27.6 VDC |
| Charge voltage absorption (adjustable) | 28.8 VDC |
| Charge algorithm | Adaptive, 4-stage |
| Nominal battery voltage | 24 V |
| Auxiliary AC output | Yes |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| Three phase operation | Yes |
| Zero load power in search mode | 3 W |
| Zero load power in AES mode | 9 W |
| Zero Load Power | 13 W |
| Transfer switch AC current rating | 50 A |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| Temperature Sensor | Included |
| Remote terminal | On / Off |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Programmable relay | AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| PowerControl | Yes |
| PowerAssist | Yes |
| Peak power rating | 5,500 W |
| Parallel operation | Yes |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Number of AC Outputs | 2 |
| AC Input voltage range | 90 to 140 VAC |
| AC input frequency range | 45 to 65 Hz |
| AC connection terminal type | Screw terminals 13 mm2 (6 AWG) |
| Battery connection terminal type | M8 bolts |
| Relay terminal type | Screw terminal 3-pole |
| Remote terminal type | Screw terminal two pole |
| VE.bus communication port | Two RJ45 terminals |
- MultiPlus-II 24/3000/70-50
- Temperature sensor
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.
Alternative Products
These other products might interest you