At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- PowerAssist adds battery power when AC power is limited
- Connects to a Cerbo GX for monitoring and control over VE.Bus
- Can run in parallel or three-phase systems
Key specs
- AC Input voltage range: 90 to 140 VAC
- Maximum AC input current: 95 A
- Peak power rating: 9,000 W
- Maximum efficiency: 96 %
- Operating temperature range (fan assisted cooling): -40 to 65 C
| Specification | Value |
|---|---|
| AC Input voltage range | 90 to 140 VAC |
| Communication Port | VE.Bus |
| Charge voltage storage (adjustable) | 52.8 VDC |
| Charge voltage float (adjustable) | 55.2 VDC |
| Charge voltage absorption (adjustable) | 57.6 VDC |
| Charge algorithm | Adaptive, 4-stage |
| Nominal battery voltage | 48 V |
| Auxiliary AC output | Yes |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| AC input frequency range | 45 to 65 Hz |
| General purpose communication port | Yes |
| Maximum AC input current | 95 A |
| PowerAssist | Yes |
| Peak power rating | 9,000 W |
| Parallel operation | Yes |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Number of AC Outputs | 2 |
| Number of AC Inputs | 1 |
| Maximum charge current (up to 25 C ambient) | 70 A |
| Maximum humidity (non-condensing) | 95 % |
| Maximum efficiency | 96 % |
| PowerControl | Yes |
| Fan assisted cooling | Yes |
| External AC Current Sensor | 100A (optional) |
| DC Input voltage range | 38 to 66 VDC |
| Continuous inverter AC output power at 65 C | 3,000 W |
| Continuous inverter AC output power at 40 C | 3,700 W |
| Continuous inverter AC output power at 25 C | 4,000 W |
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 5,000 VA |
| Programming via computer or app | Yes |
| Zero load power in search mode | 3 W |
| Zero load power in AES mode | 10 W |
| Zero Load Power | 15 W |
| Transfer switch AC current rating | 95 A |
| Three phase operation | Yes |
| Temperature Sensor | Included |
| Remote terminal | On / Off / Charger only |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Programmable relay | AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| VE.bus communication port | Two RJ45 terminals |
| Remote terminal type | Screw terminal two pole |
| Relay terminal type | Screw terminal 3-pole |
| Battery connection terminal type | M8 bolts |
| AC connection terminal type | Screw terminals 35 mm2 (2 AWG) |
- MultiPlus-II 48/5000/70-95
- Temperature sensor
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.