At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- Two AC inputs for shore power and a generator
- Connects to a Cerbo GX for monitoring and control over VE.Bus
Key specs
- DC Input voltage range: 9.5 to 17 VDC
- Continuous inverter AC output power at 25 C: 2,400 W
- Peak power rating: 5,500 W
- Maximum efficiency: 93 %
- Protection category: IP22
| Specification | Value |
|---|---|
| Charge voltage float (adjustable) | 13.8 VDC |
| Fan assisted cooling | Yes |
| External AC Current Sensor | 100A (optional) |
| DC Input voltage range | 9.5 to 17 VDC |
| Continuous inverter AC output power at 65 C | 1,700 W |
| Continuous inverter AC output power at 40 C | 2,200 W |
| Continuous inverter AC output power at 25 C | 2,400 W |
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 3,000 VA |
| General purpose communication ports (2x) | Yes |
| Communication Port | VE.Bus |
| Charge voltage storage (adjustable) | 13.2 VDC |
| Maximum AC input current on each leg | 50 A |
| Charge voltage absorption (adjustable) | 14.4 VDC |
| Charge algorithm | Adaptive, 4-stage |
| Nominal battery voltage | 12 V |
| Auxiliary AC output each leg | Yes |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| AC Input voltage range split phase | 180 to 280 VAC |
| AC Input voltage range single phase | 90 to 140 VAC |
| AC input frequency range | 45 to 65 Hz |
| Battery temperature sensor | Included |
| Zero load power in search mode | 4 W |
| Zero load power in AES mode | 10 W |
| Zero Load Power | 15 W |
| Transfer switch AC current rating | 50 A |
| Remote terminal | On / Off |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Programmable relay | AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| Peak power rating | 5,500 W |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Maximum charge current (up to 25 C ambient) | 120 A |
| Maximum humidity (non-condensing) | 95 % |
| Maximum efficiency | 93 % |
| Maximum apparent feed-in power | 2,500 VA |
| AC connection terminal type | Screw terminals 21 mm2 (4 AWG) |
| VE.bus communication port | Two RJ45 terminals |
| Remote terminal type | Screw terminal two pole |
| Relay terminal type | Screw terminal 3-pole |
| Battery connection terminal type | M8 bolts (two for positive and two for negative connection) |
| Protection category | IP22 |
| Width | 319 mm |
| Weight | 32.8 kg |
| Material | Steel |
| Height | 579 mm |
- Quattro-II 12/3000/120-50
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.
Alternative Products
These other products might interest you