At a glance
Highlights
- True sine wave inverter, battery charger and AC transfer switch in one unit
- Two AC inputs for shore power and a generator
- Connects to a Cerbo GX for monitoring and control over VE.Bus
Key specs
- Nominal battery voltage: 24 V
- Continuous inverter AC output power at 25 C: 2,400 W
- Peak power rating: 5,500 W
- Maximum efficiency: 94 %
- Operating temperature range (fan assisted cooling): -40 to 65 C
| Specification | Value |
|---|---|
| Communication Port | VE.Bus |
| Zero Load Power | 11 W |
| Continuous inverter AC output power at 25 C | 2,400 W |
| Continuous power at 25 C (Nonlinear load, crest factor 3:1) | 3,000 VA |
| General purpose communication ports (2x) | Yes |
| External AC Current Sensor | 100A (optional) |
| Zero load power in AES mode | 8 W |
| Charge voltage storage (adjustable) | 26.4 VDC |
| Charge voltage float (adjustable) | 27.6 VDC |
| Charge voltage absorption (adjustable) | 28.8 VDC |
| Charge algorithm | Adaptive, 4-stage |
| Nominal battery voltage | 24 V |
| Zero load power in search mode | 4 W |
| Continuous inverter AC output power at 40 C | 2,200 W |
| Continuous inverter AC output power at 65 C | 1,700 W |
| DC Input voltage range | 19 to 33 VDC |
| Transfer switch AC current rating | 50 A |
| Fan assisted cooling | Yes |
| Maximum AC input current on each leg | 50 A |
| Maximum apparent feed-in power | 2,500 VA |
| Maximum efficiency | 94 % |
| Maximum humidity (non-condensing) | 95 % |
| Maximum charge current (up to 25 C ambient) | 70 A |
| Operating temperature range (fan assisted cooling) | -40 to 65 C |
| Peak power rating | 5,500 W |
| Programmable relay | AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC |
| Protections | Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple |
| Remote terminal | On / Off |
| Battery temperature sensor | Included |
| AC output voltage +/-2% (adjustable) | 120 VAC |
| AC output frequency +/-0.1% (adjustable) | 60 Hz |
| AC Input voltage range split phase | 180 to 280 VAC |
| AC Input voltage range single phase | 90 to 140 VAC |
| AC input frequency range | 45 to 65 Hz |
| Auxiliary AC output each leg | Yes |
| Battery connection terminal type | M8 bolts |
| AC connection terminal type | Screw terminals 21 mm2 (4 AWG) |
| Relay terminal type | Screw terminal 3-pole |
| Remote terminal type | Screw terminal two pole |
| VE.bus communication port | Two RJ45 terminals |
| Height | 579 mm |
| Material | Steel |
| Depth | 168 mm |
| Colour | Blue (RAL 5012) |
| Weight | 22.5 kg |
- Quattro-II 24/3000/70-50/50
Battery cables, fuses and a GX device are sold separately.
Use thick battery cables and a fuse close to the battery. Set the AC input limit and charge settings with VictronConnect or VEConfigure.
We install Victron systems at our shops in Salt Lake City, Utah and Fort Collins, Colorado. See our installation page or send us an inquiry.
5 year warranty. Read Victron's warranty terms.
Ships in 1 to 5 business days.
Alternative Products